The complete solution for monitoring of temperature, humidity, pressure, CO2, voltage, current, pulses, events and other signals. Universal configurable inputs and outputs. For desktop use with rubber feet – see Optional accessories. For mounting to 19″ rack – one rack unit 1U.
Data loggers are designedfor measuring, recording, evaluation and subsequent processing ofinput electrical signals, which are subject torelativelyslow changes (> 1s). In conjunctionwith the appropriatesensorsandtransducers are suitableformonitoringphysical quantities. The device includestraceable calibration certificatewith declaredmetrological traceability ofetalons is based onrequirements of ENISO/IEC17025.The calibrationsheetisalwaysloadedasmodules. If thedefined requiredconfiguration of inputs by, calibration certificate proves calibrationinputsaccording totherequired configuration –more thanone range foreach of the16 inputs.
Memory typeinternal SRAM, backed-up by Lithium battery
Recording intervaladjustable individually for all input channels from 1 second to 24 hours
Recording intervalnoncyclic – data logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Real time clockyear, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels)16 bits, conversion duration approximately 60ms/channel
Communication speed9600, 19200, 57600, 115200 Bd, 230400* Bd (* pro USB, Ethernet)
Power24 Vdc
Protection classIP20
Dimensions (including connectors)225 x 230 x 44 mm – one rack unit 1U
Dimensions without rack holders225 x 230 x 44 mm – one rack unit 1U
Weightapprox. 800 g
Warranty3 years
Device enables:
to measure and process 1 to 16 input signals
to acquire autonomous time record of measured values
create alarm states
to perform other actions based on created alarms (audible, visual indication, controlling of relay outputs, sending SMS message, controlling of telephone dialer, sending of messages via several protocols of the Ethernet interface etc.)
to monitor on-line measured values and states
independent hysteresis setting, delay (for each channel separately)
setting up to four alarm conditions (for each channel separately)
Common connectivity options:
Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible. The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network.
Parameters and measuring ranges of configurable inputs MS6D
The monitoring systems MS6xx is equipped with 16 freely programmable universal inputs. Each of them can be set to the input signal according to the table below. The monitoring system is thus very flexible and offers ease of use. The RS485 input must be ordered separately if you want to use the Modbus or Advantech communication interface.
Main features:
software configurable inputs for temperature sensors Pt and Ni, thermocouples and thermistors, voltage and current, two-state events, resistance, sensors with RS485 output
memory for 500 000 records with automatic downloading to PC
alarm indication via integrated siren, e-mail, SMS and two-state output to control other devices