The complete solution for monitoring of temperature, humidity, pressure, CO2, voltage, current, pulses, events and other signals. Configurable inputs and outputs.
Data loggers are designedfor measuring, recording, evaluation and subsequent processing ofinput electrical signals, which are subject torelativelyslow changes (> 1s). In conjunctionwith the appropriatesensorsandtransducers are suitableformonitoringphysical quantities.
The device includestraceable calibration certificatewith declaredmetrological traceability ofetalons is based onrequirements of ENISO/IEC17025.The calibrationsheetisalwaysloadedasmodules. If thedefined requiredconfiguration of inputs by, calibration certificate proves calibrationinputsaccording totherequired configuration –more thanone range foreach of the16 inputs.
Warranty: 3 years
INCLUDED IN DELIVERY:
MS55D
Instruction Manual
Traceable Calibration Certificate
EXTERNAL PROBES ARE NOT INCLUDED IN DELIVERY
MEASURED VALUE
Temperature
Relative humidity
Counted values (dew point…)
Current
Voltage
Two-state signal
Pulses
Frequency
Resistance
Event logging
GENERAL TECHNICAL DATA
Operating temperature0 to +50 °C
Channels1 to 16 hardware modules
Memory2MB (up to 480 000 values)
Memory typeinternal SRAM, backed-up by Lithium battery
Recording intervaladjustable individually for all input channels from 1 second to 24 hours
Recording intervalnoncyclic – data logging stops after filling the memory
cyclic – after filling memory oldest data is overwritten by new
Real time clockyear, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Resolution of the AD converter (analog channels)16 bits, conversion duration approximately 60ms/channel
Communication speed9600, 19200, 57600, 115200 Bd, 230400* Bd (* pro USB, Ethernet)
Power9 to 30Vdc, 24Vdc recommended
Protection classIP20
Dimensions (including connectors)215 x 225 x 60 mm
Weightapprox. 800 g
Warranty3 years
Device enables:
to measure and process 1 to 16 input signals
to acquire autonomous time record of measured values
create alarm states
to perform other actions based on created alarms (audible, visual indication, controlling of relay outputs, sending SMS message, controlling of telephone dialer, sending of messages via several protocols of the Ethernet interface etc.)
to monitor on-line measured values and states
independent hysteresis setting, delay (for each channel separately)
setting up to four alarm conditions (for each channel separately)
Common connectivity options
Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible.
The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network.
modular inputs for temperature sensors Pt and Ni, thermocouples and thermistors, voltage and current, two-state events, frequency and pulses, resistance, sensors with RS485 output
memory for 500 000 records with automatic downloading to PC
alarm indication via integrated siren, e-mail, SMS and two-state output to control other devices
Reviews